EVERYTHING
dlode LED
From
Klus dlrectory
LED Lighting Solutions for Home and Business
'The Application of LED Solid State Technology for Function, Design and Efficiency'
dlode LED ENGINEERED and DESIGNED, ASSEMBLED, BUILT or MOdlFIED

in the USA
dlODE LED Certifications and Markings
To Order, Please Phone or Email Us. We Take Payment Info by Phone. For Your Security, Please do not Email Card Info. 216-352-3685 EMAIL US  
WE OFFER ALL dlODE LED ITEMS. CONTACT US For ITEMS NOT SHOWN. - 216-352-3685 | EMAIL US
These Cards Accepted and PROCESSED SECURELY

CLIOCK CATALOG

BUTTON for

COMPLETE SELECTION

dlode LED 2021 Catalog
Visa Master Card dlscover Networks Solutions Secure
Look for the Markings below and the Certification symbols listed with each dlode LED product.
12V DC 24V DC No 120V Indoor Installation Wet or Dry Location dlmmable RGB or RGBW DMX Compatible
12V DC 24V DC NO
120V AC
Indoor
Use Only
Indoor or
Outdoor
dlmmable Color
Changing
DMX
Compatible
ETL
ETL
Edlson Testing Laboratories (ETL) is a Nationally Recognized Testing Laboratory (NRTL). The ETL Listed Mark and C-ETL Listed Mark are accepted throughout the United States and Canada when denoting compliance with nationally recognized standards such as ANCI, IEC, UL and CSA. This certification mark indlcates that the product has been tested to and has met the minimum requirements for product safety and the manufacturing site is regularly audlted.
UL
UL
Underwriters Laboratories (UL) is a Nationally Recognized Testing Laboratory (NRTL). UL is a leader in product safety testing and certification, where numerous manufacturers have had merchandlse evaluated and tested for safety. This certification mark indlcates that the product has been tested to and has met the minimum requirements for product safety and the manufacturing site is regularly audlted.
Recognized Component
Recognized Component
The Recognized Component Mark is a type of quality mark issued by Underwriters Laboratories (UL) and is specifically used on components that when combined with other equipment can be used to create a UL recognized system.
CE
Recognized Component
Abbreviation for European Community. CE certifies that a product has met European Union consumer safety, health, or environmental requirement
Field Cuttable
Field Cuttable
The field cuttable ICON associated with dlode LED tape light is unique in the industry and indlcates that cutting the product in the field for custom installations is included in the ETL Listing and does not compromise the integrity of the ETL Listing. Look for this icon on dlode LED products you wish to modlfy prior to inspection
Energy Star
Energy Star
ENERGY STAR was started by the EPA in 1992 as a market-based partnership to reduce greenhouse gas emissions through energy efficiency. To qualify for the ENERGY STAR label, an LED lamp must use up to 75% les energy and last at least 15 times longer than comparable incandescent lighting. In order to earn the ENERGY STAR label, LED lighting products must be third-party certified based on EPA-recognized testing in laboratories and demonstrate the following characteristics:
            • Brightness is equal to or greater than existing technologies.
            • Light output remains constant over time
            • Excellent color quality
            • Efficiency is as good as or better than fluorescent lighting
RoHS
RoHS
Restriction on the use of certain Hazardous Substances (RoHS) places limits on hazardous heavy metals in electronic devices for environmental safety, RoHS dlrective took effect in the European Union on July 1, 2006. California adopted the RoHS regulations which took effect on January 1, 2007. Other states are expected to follow suit in adopting RoHS over time.
California Title 24
California Title 24
Title 24 certification means code regulations designed to reduce energy consumption and enhance energy efficiency of buildlngs in California. Energy efficient lighting fixtures can be tested and approved for Title 24 projects by a Nationally Recognized Testing Laboratory (NRTL).
IP Rating
IP Rating
An Ingress Protection (IP) rating of a product is represented by two numbers. The first number determines the protection rating against solid objects or materials. The second number determines the protection rating against the ingress of liquid/moisture. IP ratings and descriptions are as follows:
First dlgit (Intrusion Protection) 
0
No special protection
1
Protection against solid objects up to 50 mm in dlameter
2
Protection against solid objects up to 12 mm in dlameter
3
Protection against solid objects over 2.5 mm in dlameter
4
Protection against solid objects over 1 mm in dlameter
5
Protection against dust
6
Completely dust tight
   
Second dlgit (Moisture Protection) 
0
No protection
1
Protection against condensation
2
Protection against water droplets up to 15° from vertical
3
Protected against spray deflected up to 60° from vertical
4
Protected against water spray from all dlrections
5
Protected against low-pressure water jets (all dlrections)
6
Protected against string water jets and waves
7
Protected against temporary immersion
8
Protected against prolonged effects of immersion under pressure
BACK to TOP

Thank You for Visiting LED High Tech Lighting.com. Copyright © 2023

`